EAN-13 Barcode Dimensions
Barcode Standards
Symbol Dimensions (at 100% magnification):
Barcode Magnification Standards:
The allowable magnification range for an EAN-13 Barcode Symbol is POS 80% – 200% (X-dimension 0.26mm-0.66mm).
Note: To find the overall bar code width required (from the table below), you must include the Left & Right Quiet Zone dimensions (as well as the “Bar Width” dimensions). Therefore, a barcode at 80% magnification must be at least 29.83mm wide.
Dimensions (All measurements in millimetres)
| Magnification | X-dimension | Width | Bar height | Left Quiet Zone | Right Quiet Zone |
|---|---|---|---|---|---|
| 0.80 | 0.26 | 25.08 | 18.28 | 2.90 | 1.85 |
| 0.85 | 0.28 | 26.65 | 19.42 | 3.09 | 1.96 |
| 0.90 | 0.30 | 28.22 | 20.57 | 3.27 | 2.08 |
| 0.95 | 0.31 | 29.78 | 21.71 | 3.45 | 2.19 |
| 1.00 | 0.33 | 31.35 | 22.85 | 3.63 | 2.31 |
| 1.05 | 0.35 | 32.92 | 23.99 | 3.81 | 2.43 |
| 1.10 | 0.36 | 34.49 | 25.14 | 3.99 | 2.54 |
| 1.15 | 0.38 | 36.05 | 26.28 | 4.17 | 2.66 |
| 1.20 | 0.40 | 37.62 | 27.42 | 4.36 | 2.77 |
| 1.25 | 0.41 | 39.19 | 28.56 | 4.54 | 2.89 |
| 1.30 | 0.43 | 40.76 | 29.71 | 4.72 | 3.00 |
| 1.35 | 0.45 | 42.32 | 30.85 | 4.90 | 3.12 |
| 1.40 | 0.46 | 43.89 | 31.99 | 5.08 | 3.23 |
| 1.45 | 0.48 | 45.46 | 33.13 | 5.26 | 3.35 |
| 1.50 | 0.50 | 47.03 | 34.28 | 5.45 | 3.47 |
| 1.55 | 0.51 | 48.59 | 35.42 | 5.63 | 3.58 |
| 1.60 | 0.53 | 50.16 | 36.56 | 5.81 | 3.70 |
| 1.65 | 0.54 | 51.73 | 37.70 | 5.99 | 3.81 |
| 1.70 | 0.56 | 53.30 | 38.85 | 6.17 | 3.93 |
| 1.75 | 0.58 | 54.86 | 39.99 | 6.35 | 4.04 |
| 1.80 | 0.59 | 56.43 | 41.13 | 6.53 | 4.16 |
| 1.85 | 0.61 | 58.00 | 42.27 | 6.72 | 4.27 |
| 1.90 | 0.63 | 59.57 | 43.42 | 6.90 | 4.39 |
| 1.95 | 0.64 | 61.13 | 44.56 | 7.08 | 4.50 |
| 2.00 | 0.66 | 62.70 | 45.70 | 7.26 | 4.62 |
“Width”
the width of the bars only (does not include the width of the Left & Right Quiet Zones – the quiet zone widths are just as important).
“Bar Height”
the height of the bars only. You need to allow extra space to include the barcode number, which must be printed below the bars.
“Quiet Zone”
the blank space on either side of the barcode. These are compulsory as scanners need them in order to read the barcode bars.
A minimum allowable magnification of 75% (X-dimension 0.25mm) applies only to on-demand (e.g. thermal) print processes. In this case, the bar height should never be truncated below the minimum required height for an 80% magnification barcode symbol.
Where an item may also be scanned in a general distribution scanning environment (automated scanning), the allowable magnification range is 150% to 200% (X-dimension 0.50mm – 0.66mm).
Feedback
“Many thanks for the prompt service and supply of the barcodes. I found your website very informative, I have a brand new business with new products, and I knew nothing about how bar codes worked or how to go about acquiring them. Your website answered all my questions and more and gave me the confidence to place an order, and you haven’t disappointed with your service.” Martin