Click to Buy barcodes

Barcode Dimensions

 

EAN-13 Barcode Symbol Dimensions (at 100% magnification):

 

Barcode Magnification Standards:

The allowable magnification range for an EAN-13 Barcode Symbol is POS 80% – 200% (X-dimension 0.26mm-0.66mm).

Note: To find the overall bar code width required (from the table below) you must include the Left & Right Quiet Zone dimensions (as well as the “Bar Width” dimensions). Therefore,  a barcode at 80% magnification needs to be at least 29.83mm wide.

Magnification

X-dimension

Bar Width

Bar Height

Left Quiet Zone

Right Quiet Zone

80%

0.26

25.08

18.28

2.90

1.85

85%

0.28

26.65

19.42

3.09

1.96

90%

0.30

28.22

20.57

3.27

2.08

95%

0.31

29.78

21.71

3.45

2.19

100%

0.33

31.35

22.85

3.63

2.31

105%

0.35

32.92

23.99

3.81

2.43

110%

0.36

34.49

25.14

3.99

2.54

115%

0.38

36.05

26.28

4.17

2.66

120%

0.40

37.62

27.42

4.36

2.77

125%

0.41

39.19

28.56

4.54

2.89

130%

0.43

40.76

29.71

4.72

3.00

135%

0.45

42.32

30.85

4.90

3.12

140%

0.46

43.89

31.99

5.08

3.23

145%

0.48

45.46

33.13

5.26

3.35

150%

0.50

47.03

34.28

5.45

3.47

155%

0.51

48.59

35.42

5.63

3.58

160%

0.53

50.16

36.56

5.81

3.70

165%

0.54

51.73

37.70

5.99

3.81

170%

0.56

53.30

38.85

6.17

3.93

175%

0.58

54.86

39.99

6.35

4.04

180%

0.59

56.43

41.13

6.53

4.16

185%

0.61

58.00

42.27

6.72

4.27

190%

0.63

59.57

43.42

6.90

4.39

195%

0.64

61.13

44.56

7.08

4.50

200%

0.66

62.70

45.70

7.26

4.62

“Width” = the width of the bars only (does not include the width of the Left & Right Quiet Zones – the quiet zone widths are just as important).

“Bar Height” = the height of the bars only. You need to allow extra space to include the barcode number (which must be printed below the bars).

“Quiet Zone” = the blank space on either side of the barcode. These are compulsory (scanners need them in order to read the barcode bars).

An allowable minimum magnification of 75% (X-dimension 0.25mm) is applicable only to on demand (e.g. thermal) print processes. In this case, the bar height should never be truncated below the minimum required height for an 80% magnification barcode symbol.

Where an item may also be scanned in a General Distribution Scanning environment (automated scanning), the allowable magnification range is 150% to 200% (X-dimension 0.50mm – 0.66mm).